Case history · Industrial water reuse

IN-CO: ELETTROFLOTTAZIONE® connected to Industry 4.0.

A long-running industrial application combining closed-loop wastewater treatment, plant revamping and remote IIoT supervision for the production of bimetallic and trimetallic electrical contacts.

01ELETTROFLOTTAZIONE®PROCESS WATER TREATMENT
02RECOVERY LOOPNO FINAL LIQUID DISCHARGE
03IIoTREMOTE SUPERVISION
1963Company origin
1994Quality-management system
May 2000Investment in ELETTROFLOTTAZIONE®
May 2013Automation revamping and Rilheva IIoT
2018UNI EN ISO 9001:2015 certification

01 · Profile

The client

IN-CO originated in 1963 as Renato Romagnoni and manufactures bimetallic and trimetallic electrical contacts. Its production capabilities evolved within a modern 2,500 m² facility, supported by specialised personnel and advanced machinery. The company has applied a quality-management system since 1994 and obtained UNI EN ISO 9001:2015 certification in 2018. Massimo, Alessandra, Paolo and Claudio continue the family tradition through continuous renewal, Made in Italy manufacturing and the transition towards Industry 4.0.

02 · Process

Need and original solution

Driven by innovation and environmental-impact reduction, IN-CO invested in ELETTROFLOTTAZIONE® in May 2000. The objective was to treat and recover process wastewater without a final liquid discharge. Over years of operation, the company developed direct operating experience. According to the published case history, nearly all of the limited shutdown events were linked to isolated, very small anomalies in ageing components—conditions that could neither be anticipated by an operator nor managed when no operator was present locally.

03 · Upgrade

2013 revamping and remote supervision

In May 2013, Stefano Sommariva, supplier of the ELETTROFLOTTAZIONE® technology, revamped the plant with a new automation control panel and Rilheva supervision. Real-time plant visibility and remote supplier support became available from that point onward. The original case history reports that external assistance costs and failure-related interruptions during normal operation were practically eliminated.

04 · IIoT

Rilheva IIoT platform

The web-based SCADA platform was introduced to improve process awareness, operational efficiency and remote access to the plant.

05 · Results

Operational benefits

01

Continuous awareness

Operators and production management can verify the actual plant status and the active process phase at any time.

02

Remote intervention

The installation can be supervised and managed from another department, reducing unnecessary movement within the facility.

03

Immediate alarms

Anomalies are reported in real time to both the plant operator and the production manager, including information on the event type.

04

Control and cost reduction

The reported outcome combines total control, improved operating safety and a substantial reduction in external service costs.